NEC UNIVERGE UM8500 Integration Manual page 218

Hide thumbs Also See for UNIVERGE UM8500:
Table of Contents

Advertisement

UNIVERGE UM8500 I
208
TMFC-Record.
Enter the Terminal Mode Function Code for the Record
command for Live Record. The default value is 192 as this is the predefined
function in the phone system, but can be changed if needed.
TMFC-Pause.
Enter the Terminal Mode Function Code for the Pause
command for Live Record. The default value is 193 as this is the predefined
function in the phone system, but can be changed if needed.
TMFC-ReRecord.
Enter the Terminal Mode Function Code for the ReRecord
command for Live Record. The default value is 194 as this is the predefined
function in the phone system, but can be changed if needed.
TMFC-End.
Enter the Terminal Mode Function Code for the End command
for Live Record. The default value is 195 as this is the predefined function in
the phone system, but can be changed if needed.
KC-Record.
Enter the OAI Key Code used for the Record command on a
Dterm function key. To disable monitoring of the key, enter 0 or a negative
number. The default value is 1.
KC-Pause.
Enter the OAI Key Code used for the Pause/Resume command on
a Dterm function key. To disable monitoring of the key, enter 0 or a negative
number. The default value is 2.
KC-Rerecord.
Enter the OAI Key Code used for the ReRecord command on a
Dterm function key. To disable monitoring of the key, enter 0 or a negative
number. The default value is 3.
KC-End:.
Enter the OAI Key Code used for the End command on a Dterm
function key. To disable monitoring of the key, enter 0 or a negative number.
The default value is 4.
ToggleStartStop.
This feature allows the user to press a single key to start,
stop, or restart a Live Record session. To enable the feature, enter True. To
disable the feature, enter False. The default value is True.
6
If using a template that enables the MCI-LAN integration, in the navigation
panel of the configuration file, expand the MCI-LAN node.
NOTE
Do not complete this step if a template other than the NEC
SV7000 - OAI-UCD-MCI LAN template, where the PBX cmd ASYDL
Sys 1 Index 833 Bit 0 value = 1, was selected.
The settings must match the settings for the phone system for the MCI LAN
connection.
LAN-IP.
Enter the IP address of the phone system. This should be the same
as the address entered in the CallPilot1 section under the PBX-IP. The default
value is just an example and must be changed to match the phone system
setting.
Format.
Enter the format of the MCI-LAN packets expected from the phone
system. Enter
for regular (ICS/IVS) packets, or
ICS
packets. The default is IMX.
Parity.
Enter the parity or checksum used by the phone system to process
the MCI-LAN packets. Accepted values are
is Odd.
LocalPort.
Enter the local port used by the MCI-LAN integration module for
a TCP/IP connection to the phone system. Accepted values are any valid TCP/
IP port. The default is 60120. Do not change this value unless you know that
this port is already taken by other applications on the UNIVERGE UM8500
server.
DeviceID.
Enter the device ID used by the MCI-LAN integration module to
identify itself to the MCI interface on the phone system. Accepted values are 0
and 1. The default is 1.
G
NTEGRATION
UIDE
for expanded (IMX)
IMX
None
Even
Odd
,
, or
. The default

Advertisement

Table of Contents
loading

Table of Contents