NEC UNIVERGE UM8500 Integration Manual page 137

Hide thumbs Also See for UNIVERGE UM8500:
Table of Contents

Advertisement

To set the UCD hunt group configuration
IMPORTANT
Only adjust the UCD hunt group settings if the OAI UCD with Serial
MCI integration is being used.
Verify the following configurations and settings.
1
Verify that t
he UCD group is set to: 220-223.
Verify that t
2
he UCD pilot is set to: 220.
Command
170>220:NONE-221
170>221:NONE-222
170>222:NONE-223
170>223:NONE-220
172>220:NONE-01
172>221:NONE-01
172>222:NONE-01
172>223:NONE-01
171>220:0-1
1310>220:0
1310>221:0
1310>222:0
1310>223:0
To set OAI monitored function keys for Live Record
If the Live Record feature will be used in the phone system, verify that the system
has the following settings or that the configuration files are updated.
1
The OAI LiveRecord feature uses the following settings by default.
WARNING!
If these defaults are changed, the corresponding settings in the
OAI Integration Server must be set up accordingly by editing the
XML configuration file.
Dterm
Function
Function
Code
Key
09
F1032
10
F1033
11
F1034
12
F1035
2
When using LiveRecord, the monitored extensions or voice ports are allowed
to use Executive-Override with the LiveRecord feature. Normally, the OAI
monitoring is set by CMD17,Y=1, Extension>3, but this value will
automatically activate the Off-Hook Suppress bit. Instead, the
UNDOCUMENTED value of 4 that will take the Off-Hook Suppress OFF is
used.
3
The Executive Override code programmed on the command 200>A4>A006,
for example, should match the BargeInCode parameter setting in the
UNIVERGE UM8500 integration file. In this case the code is *4 and the
UM8500 entry is BargeInCode = X,&,*4.
Description
Set up the 220-223 range as a UCD hunt group.
Set the 220-223 range as part of Group 01, other
than the OAI group (00) of the monitored
number(s).
Set extension 220 to be the UCD pilot (master).
Set the 220-223 range as messaging system (VMS)
stations (for MCI / J-records appearance).
Terminal Mode
LiveRecord
Facility (TMF)
Function
Code
192
Record
193
Pause/Resume
194
Re-record
195
End
NEC NEAX 2000
WITH
OAI
127

Advertisement

Table of Contents
loading

Table of Contents