NEC UNIVERGE UM8500 Integration Manual page 167

Hide thumbs Also See for UNIVERGE UM8500:
Table of Contents

Advertisement

4
Specify a Service Feature Restriction Class (SFC) for the voice messaging
ports, see the ASFC command. It is recommended that all voice messaging
ports be placed in their own SFC. The following Service Feature Indexes (SFIs)
are needed in the SFC:
SFI
Service feature
10
Call hold
103
Assignment of no answer timer for blind transfer
to station or blind transfer to attendant
104
Blind transfer
5
Assign all of the voice messaging ports to a Uniform Call Distribution (UCD)
group (see command ASHU).
NOTES
Logical numbers appear only in a NEC Fusion network and are used
to uniquely identify all the extensions in the network.
If the phone system that hosts the voice messaging ports extensions
is part of a NEC Fusion network and those ports need to be accessible
from the other Fusion nodes, then the UCD must be configured to
contain the logical numbers corresponding with the ports extensions,
see the commands ALGSN, ASHUN.
CAUTION
Do not use a phantom single line extension for the UCD pilot
number.
6
Complete programming the phone system. See
the phone
system"
on page
To complete programming the phone system
1
Program each phone to forward calls to the UCD pilot number assigned to
the voice messaging system ports, based on the UM8500 call transfer type:
Release to switch transfer.
UCD pilot number when:
The extension is busy;
or,
The call is not answered.
Supervised transfer.
number only when the call is not answered. Confirm that call forwarding is
disabled when the extension is busy.
2
Set up the RS-232 serial data port for AIOC settings as follows:
9600 baud
8 data bits
1 stop bit
No parity
3
If a remote maintenance modem is used, program the modem line for data
line security.
4
Use the AUCD command to program the phone system to send UCD call
information to MCI. Assign a value of
the appropriate tenant and UCD pilot numbers.
5
Use the programming system data table to program the ASYD settings. Each
bit is part of a hexadecimal number displayed in the ASYD settings. Convert
the hexadecimal number to binary to determine the individual settings.
NEC NEAX 2400
"To complete programming
157.
Program the phone to forward calls to the
Program the phone to forward calls to the UCD pilot
0
MCI Data Transfer
to the
WITH SERIAL
field for
MCI
157