NEC UNIVERGE UM8500 Integration Manual page 185

Hide thumbs Also See for UNIVERGE UM8500:
Table of Contents

Advertisement

StopBits.
Enter the stop bits used by the serial (RS-232/MCI)
communication with the phone system. Accepted values are
specially defined phone system setting. The default value is 1.
Leave all other parameters not listed above at their default values.
7
If using a template that enables the MCI-LAN integration, in the navigation
panel of the configuration file, expand the MCI-LAN node.
NOTE
Do not complete this step if a template other than the NEC NEAX
2400 - OAI-UCD-MCI LAN template, where the PBX cmd ASYDL
Sys 1 Index 833 Bit 0 value is 1, was selected.
The settings must match the phone system settings for the MCI LAN
connection.
LAN-IP.
Enter the IP address of the LAN-MCI port on the phone system.
The default value is just an example and must be changed depending on the
phone system.
NOTE
In older revisions of phone systems, the IP address of the LAN-
MCI interface is sometimes different from the IP address of the
OAI, used in the CallPilot1 section.
Format.
Enter the format of the MCI-LAN packets expected from the phone
system. Enter
for regular (ICS/IVS) packets, or
ICS
packets. The default is IMX.
Parity.
Enter the parity or checksum used by the phone system to process
the MCI-LAN packets. Accepted values are
is Odd.
LocalPort.
Enter the local port used by the MCI-LAN integration module for
a TCP/IP connection to the phone system. Accepted values are any valid
TCP/IP port. The default is 60120. Do not change this value unless you know
that this port is already taken by other applications on the UM8500 server.
DeviceID.
Enter the device ID used by the MCI-LAN integration module to
identify itself to the MCI interface on the phone system. Accepted values are 0
and 1. The default is 1.
Leave all other parameters not listed above at their default values.
8
In the navigation pane of the configuration file, expand VMSystem1 node.
Set the following parameters to configure the VMSystem1 node:
Host.
Enter the IP address of the monitored voice mail server. This will be the
same IP address entered previously in the configuration ini file. The default
value is just an example.
PortRange.
Enter the port or range of ports for the phone system tenant
hosting the voice mail ports. Ports can be set by entering a single port
number, for example
xxxx
or a combination or both, for example xxxx-xxxx,x . The default ports are
just an example.
Tenant.
Enter the PBX tenant number where the voice mail ports are set.
The default value is 1.
Leave all other parameters not listed above at their default values.
9
File > Save
Click
to save the XML configuration file.
10
Install the OAI service and test the integration.
See
"Installing and starting the OAI
None
Even
,
; a range of numbers, for example
service"
on page
NEC NEAX 2400
OAI
WITH
1
1.5
2,
,
,
or the
for expanded (IMX)
IMX
Odd
, or
. The default
;
xxxx-xxxx
176.
175