Dt800/Dt700 Multiline Basic Information Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

84-23 : DT800/DT700 Multiline Basic Information Setup

Level:
IN
Description
Use Program 84-23 : DT800/DT700 Multiline Basic Information Setup to set the basic information for
the DT800/DT700 Multiline Terminal.
Input Data
Item
No.
01
Registration Expire Timer
The Expires value of the REGISTER
message which received from DT700
terminal is out of range or when the Expire
value is not set up, in case it assigns the
effective time to the DT700 terminal. The
timer for supervising whether DT700 terminal
is connected or not.
02
Subscribe Expire Timer
The subscribe Expire timer to transmit and
receive the terminal operation instructions
between the Main Device and DT700
terminal.
03
Session Expire Timer
Set effective time for supervising the Voice
Path.
04
Minimum Session Expire Timer
Set minimum value of effective time for
supervising the Voice Path.
05
Invite Expire Timer
Set effective time for Incoming/Outgoing call
when the Expire value is not set in the
INVITE message received from DT700
terminal.
06
Signal Type of Service
Set Type of Service value which applied to
send SIP Message Packet from DT700
terminal to Main Device.
07
Error Display Timer
2-782
Program 84 : Hardware Setup for VoIP
Item
60~65535 (sec)
60~65535 (sec)
60~65535 (sec)
60~65535 (sec)
0~65535 (sec)
0x00~0xFF
(0~9, A~F)
0~65535 (sec)
Input Data
Default
180
3600
180
180
180
Program 84 : Hardware Setup for VoIP
Issue 4.0
00
0

Advertisement

Table of Contents
loading

Table of Contents