Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-07 : CODEC Filter Setup for Analog Trunk Port to define the CODEC (QSLAC)
Filter for each analog trunk port.
Input Data
Trunk Number
CODEC Filter Type
0 = No filter
1 = Type 1: 600
Line loss 0dB (~500m from CO Ex)
2 = Type 2: 600
Line loss 4dB (1~2km from CO Ex)
3 = Type 3: 600
Line loss 8dB (~3km from CO Ex)
4 = Type 4: Enable PRG81-17 setting
Conditions
None
Feature Cross Reference
None
2-708

81-07 : CODEC Filter Setup for Analog Trunk Port

1~400
Default
2
Program 81 : Basic Hardware Setup for Trunk