Analog Trunk Data Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Issue 4.0
Level:
IN
Description
Use Program 14-02 : Analog Trunk Data Setup to set the basic options for each analog trunk port.
Refer to the table below for a description of each option, its range and default setting.
Input Data
Trunk Port Number
Item
No.
01
Signaling Type (DP/DTMF)
Set the signaling type for the trunk.
02
Ring Detect Type
Set Extended Ring Detect or
Immediate Ring Detect for the trunk.
For T1 loop/ground start trunks, this
option must be set to 1 for the trunks to
ring and light correctly.
03
Flash Type
Select the flash type (open loop flash
or ground). Always set this option for
open loop flash.
04
Hooking Type
Use Flash for Timed Flash (Program
81-01-14) or Disconnect (Program 81-
01-15). (A user implements Flash by
pressing the FLASH key while on a
trunk call.)
05
Dial Tone Detection for Manually
Accessed Trunks
Enable/Disable dial tone detection for
directly accessed trunks. If disabled,
the system outdials on the trunks
without monitoring for dial tone.
06
Pause at 1st Digit after Line Seize in
Manual Dial Mode
SV9100 Programming Manual
Program 14 : Trunk, Basic Setup
Item
0 = Dial Pulse (10 PPS)
1 = Dial Pulse (20 PPS)
2 = DTMF
0 = Normal/delayed
1 = Immediate Ringing
0 = Open Loop Flash
1 = Ground
0 = Timed Flash (Hooking)
1 = Disconnect (Cut)
0 = Dial Tone Detection Not Used
1 = Dial Tone Detection Used
0 = No Pause (No)
1 = Pause (Yes)

14-02 : Analog Trunk Data Setup

Input Data
001~400
Related
Default
Program
2
1
0
0
81-10-07
81-10-08
0
21-01-04
1
21-01-06
2-165

Advertisement

Table of Contents
loading

Table of Contents