Sip System Interconnection Setup - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Program 10 : System Configuration Setup
Level:
IN
Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system is interconnected
and define the IP address of another system, call control port number and alias address for SV9100
system interconnection.
Input Data
System Number
Item No.
Item
01
System
Interconnection
02
IP Address
03
Call Control Port
04
Dial Number
05
Keep Alive Mode
for SIP
06
SIP Profile
Conditions
None
2-42

10-23 : SIP System Interconnection Setup

001~1000
Input Data
0 = No (Disable)
1 = Yes (Enable)
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
1~65535
Up to 12 digits (0~9)
0 = Disable
1 = Enable
1 = Profile 1
2 = Profile 2
3 = Profile 3
4 = Profile 4
5 = Profile 5
6 = Profile 6
With Version 2000 or lower CPU
Software only two SIP Profiles are
supported.
Default
0
0.0.0.0
1720
None
0
1
Program 10 : System Configuration Setup