Line Load Control - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Level:
IN
Description
Use Program 90-73 : Line Load Control to set the Line Load Control settings.
Input Data
Item
No.
01

Line Load Control

02
CPU Load Factor (Low Level
Restriction)
03
Surveillance Seconds (Low Level
Restriction)
04
CPU Load Factor (High Level
Restriction)
05
Surveillance Seconds (High Level
Restriction)
06
CPU Load Factor (High Level
Restriction)
Conditions
None
Feature Cross Reference
None
2-888
Program 90 : Maintenance Program
Item
Input Data
0 = Off
1 = On
30~100%
1~10%
30~100%
1~10%
30~100%
90-73 : Line Load Control
Default
0
90
6
95
3
50
Program 90 : Maintenance Program