Dss Console Key Assignment - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Issue 4.0
Level:
SA
Description
Use Program 30-03 : DSS Console Key Assignment to customize the key assignments for 60-button
DSS Consoles. A DSS Console key can have any function with up to four digits (e.g., extension number
or Service Code).
To prevent lamp problems when reassigning DSS Console keys, clearing an extension programmed key
before reassigning it is recommended [Enter key to be cleared + 00 or
Programming, delete the key assignments and upload the change to the system before proceeding.)]
Without clearing an extension key first, the DSS Console may not show the correct lamp display,
although the DSS function works correctly.
If you are programming the system from the extension to which the DSS Console is connected, either by
phone or using the WebPro or PC Programming, you may need to unplug the DSS and plug it back in to
reset the console lamping.
Input Data
Index 1
DSS Console Number
Item
Key Number
No.
01
001~114
SV9100 Programming Manual
Program 30 : DSS/DLS Console Setup

30-03 : DSS Console Key Assignment

Function Number
0~99 (General Functional Level)
97 = Door Box Access key
(additional data: 1~8 Door Box No.)
00 ~
99 (Appearance Functional
Level)
00 (If using WebPro or PC
01~32
Additional Data
Refer to
Function Number
List
on the following pages.