Netlink Timer Settings - NEC univerge SV9100 Programming Manual

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Level:
IN
Description
Use Program 51-05 : NetLink Timer Settings to set the various timers in the NetLink system.
Input Data
Item
No.
01
Keep Alive Sending Interval
Set the Keep Alive sending interval time from the Secondary
system to confirm communication with the Primary system.
02
Keep Alive Response Waiting Time
Set the time the Secondary system waits for a response from
the Primary system before cutting off communication.
03
Primary Search Packet Sending Interval
While searching the Primary system, the system sends a
packet at this interval.
04
Primary Search Time Maximum Value
Total Primary system seek time.
05
Top Priority Primary Detection Packet Sending Interval
When current Primary system is not Top Priority Primary
System, the system sends packet to check if Top Priority
System exists.
06
Primary Compulsion Specification Trial Maximum Time
When the forced change Primary command is executed, the
system searches the new Primary system for this time.
07
Socket Refresh Time
If the IP connection becomes unstable, the keep-alive function
does not work. If there is no data traffic for this time, the
socket is refreshed.
Conditions
None
2-654
Program 51 : NetLink Service

51-05 : NetLink Timer Settings

Item
Input Data
Default
1~3600 (sec)
5
0, 5~3600 (sec)
20
(0 = infinity)
1~3600 (sec)
5
5~10800 (sec)
20
1~3600 (sec)
10
1~10800 (sec)
30
20~3600 (sec)
40