NEC univerge SV9100 Programming Manual page 52

Hide thumbs Also See for univerge SV9100:
Table of Contents

Advertisement

Item
No.
03
--- Not Used ---
04
Layer 3 Timer Type
Each timer value of Layer 3
is set up for each type in
Program 81-06 (T-Bus)
05
CLIP Information
Based on this setting, the system
includes a Presentation Allowed (1) or
Presentation Restricted (0) in the Setup
message to allow or deny the Calling
Party Number. Program 15-01-04 must
also be set to 1 if this option is enabled.
06
Length of Cable
07
--- Not Used ---
08
Dial Sending Mode
ISDN Protocol definition
09
Dial Information Element
ISDN Protocol definition (Only when
Dialing Sending Mode (10-03-08) is set
for 1 (Overlap Sending)
10
Master/Slave System
If set to 0, system is synchronized to the
network clock. If set to 1, system is not
synchronized to the network clock. (For
NW Mode)
11
Networking System No. (for NW
Mode)
13
Loss-Of-Signal Detection Limit
If the transmit/receive voltage is less
than the setting in 10-03-13, the system
considers this as Loss-Of-Signal and
the PRTA does not come up.
14
--- Not Used ---
15
--- Not Used ---
2-12
Item
1~5
0 = Disable
1 = Enable
0 = Level 1 (0~40m)
1 = Level 2 (40~81m)
2 = Level 3 (81~122m)
3 = Level 4 (122~162m)
4 = Level 5 (162~200m)
0 = Enbloc Sending
1 = Overlap Sending
0 = Keypad Facility
1 = Called Party Number
0 = Slave System
1 = Master System
0~50
0 = Level 0 (lowest sensitivity)
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
5 = Level 5
6 = Level 6
7 = Level 7 (highest sensitivity)
Input Data
Program 10 : System Configuration Setup
Issue 4.0
Default
1
1
2
0
0
0
0
2

Advertisement

Table of Contents
loading

Table of Contents