2.1.9 Main Menu Mode

2
2
Start main menu mode by pressing the [Main Menu] key.
The readout shown to the right appears on the display.
The middle and bottom sections on the display show a list
of parameter groups which can be chosen by toggling the
up and down buttons.
Each parameter has a name and number which remain the
same regardless of the programming mode. In main menu
mode, the parameters are divided into groups. The first
digit of the parameter number (from the left) indicates the
parameter group number.
All parameters can be changed in the Main Menu.
However, depending on the choice of configuration
(1-00 Configuration Mode), some parameters can be
"missing". For example, open-loop hides all the PID
parameters, and other enabled options make more
parameter groups visible.

2.1.10 Parameter Selection

In main menu mode, the parameters are divided into
groups. Select a parameter group with the navigation keys.
The following parameter groups are accessible:
After selecting a par. group, choose a parameter by means
of the navigation keys.
The middle section on the display shows the parameter
number and name as well as the selected parameter value.
2-8
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
1107 RPM
3.84 A
Main Menu
0 - ** Operation/Display
1 - ** Load/Motor
2 - ** Brakes
3 - ** Reference / Ramps
740RPM
10.64A
Basic Settings
0 -01 Language
[0] English
MG33MD22 - VLT
2.1.11 Changing Data
The procedure for changing data is the same whether you
select a parameter in the quick menu or the main menu
mode. Press [OK] to change the selected parameter.
The procedure for changing data depends on whether the
selected parameter represents a numerical data value or a
text value.
1 (1)

2.1.12 Changing a Text Value

If the selected parameter is a text value, change the text
value with the [
The up key increases the value, and the down key
decreases the value. Place the cursor on the value you
want to save and press [OK].
2.1.13 Changing a Group of Numeric Data
Values
If the chosen parameter represents a numeric data value,
change the chosen data value by means of the [
navigation keys as well as the [
the [
] [
] navigation keys to move the cursor horizontally.
1 [1]
0-0*
Use the [
] [
] navigation keys to change the data value.
The up key enlarges the data value, and the down key
reduces the data value. Place the cursor on the value you
want to save and press [OK].
®
is a registered Danfoss trademark
] [
] navigation keys.
740RPM
10.64 A
Basic Settings
0 -01 Language
[0] English
] [
] navigation keys. Use
113 RPM
1.78 A
Load depen. setting
1 - 60 Low speed load
compensation
100%
1 [1]
0-0*
] [
]
1(1)
1- 6*