2 How to Program
Q3-40 Fan Functions
Broken Belt Function
par.22-60
par.22-61
Broken Belt Torque
Broken Belt Delay
par.22-62
par.4-64
Semi-Auto Bypass Set-up
Torque Characteristics
2
par.1-03
Low Speed Detection
par.22-22
par.22-23
No-Flow Function
No-Flow Delay
par.22-24
par.22-40
Minimum Run Time
Minimum Sleep Time
par.22-41
Wake-up Speed [RPM]
par.22-42
par.22-43
Wake-up Speed [Hz]
Wake-up Ref./FB Difference
par.22-44
par.22-45
Setpoint Boost
Maximum Boost Time
par.22-46
Brake Function
par.2-10
par. 2-16
AC Brake Max. Current
Over-voltage Control
par.2-17
par.1-73
Flying Start
Start Delay
par.1-71
Function at Stop
par.1-80
DC Hold/Preheat Current
par.2-00
Motor Speed Direction
par.4-10
See also
VLT HVAC Drive Programming Guide

2.1.7 Main Menu Mode

Select main menu mode by pressing the [Main Menu] key. The readout
below appears on the display.
The middle and bottom sections on the display show a list of parameter
groups which can be chosen by toggling the up and down buttons.
Each parameter has a name and number which remain the same regardless of the programming mode. In main menu mode, the parameters are divided
into groups. The first digit of the parameter number (from the left) indicates the parameter group number.
All parameters can be changed in the main menu. However, depending on the choice of configuration (par.1-00
can be hidden.
2-16
Q3-4 Application Settings
Q3-41 Pump Functions
Low Power Auto Set-up
par.22-20
par.22-21
Low Power Detection
Low Speed Detection
par.22-22
par.22-23
No-Flow Function
No-Flow Delay
par.22-24
Minimum Run Time
par.22-40
par.22-41
Minimum Sleep Time
Wake-up Speed [RPM]
par.22-42
par.22-43
Wake-up Speed [Hz]
Wake-up Ref./FB Difference
par.22-44
Setpoint Boost
par.22-45
par.22-46
Maximum Boost Time
Dry Pump Function
par.22-26
par.22-27
Dry Pump Delay
Flow Compensation
par.22-80
Square-linear Curve Approximation
par.22-81
par.22-82
Work Point Calculation
Speed at No-Flow [RPM]
par.22-83
par.22-84
Speed at No-Flow [Hz]
Speed at Design Point [RPM]
par.22-85
Speed at Design Point [Hz]
par.22-86
Pressure at No-Flow Speed
par.22-87
Pressure at Rated Speed
par.22-88
par.22-89
Flow at Design Point
Flow at Rated Speed
par.22-90
par.1-03
Torque Characteristics
Flying Start
par.1-73
for a detailed description of the Function Set-ups parameter groups.
MG.11.C6.22 - VLT
®
is a registered Danfoss trademark
VLT
®
HVAC Drive Programming Guide
Q3-42 Compressor Functions
Torque Characteristics
par.1-03
par.1-71
Start Delay
Short Cycle Protection
par.22-75
par.22-76
Interval between Starts
Minimum Run Time
par.22-77
Terminal 27 Mode
par.5-01
par.5-02
Terminal 29 Mode
Terminal 27 Digital Input
par.5-12
par.5-13
Terminal 29 Digital Input
Function Relay
par.5-40
Flying Start
par.1-73
par.1-86
Trip Speed Low [RPM]
Trip Speed Low [Hz]
par.1-87
Configuration Mode
), some parameters