Parameter Lists

4.1.3 0-** Operation/Display

Par.
Parameter description
No.
#
0-0* Basic Settings
0-01
Language
0-02
Motor Speed Unit
0-03
Regional Settings
0-04
Operating State at Power-up (Hand)
0-09
Performance Monitor
0-1* Set-up Operations
0-10
Active Set-up
0-11
Edit Set-up
0-12
This Set-up Linked to
0-13
Readout: Linked Set-ups
0-14
Readout: Edit Set-ups / Channel
0-15
Readout: actual setup
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-25
My Personal Menu
0-3* LCP Cust. Readout
0-30
Unit for User-defined Readout
0-31
Min Value of User-defined Readout
0-32
Max Value of User-defined Readout
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-41
[Off] Key on LCP
0-42
[Auto on] Key on LCP
0-43
[Reset] Key on LCP
0-44
[Off/Reset] Key on LCP
0-45
[Drive Bypass] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password
0-61
Access to Main Menu w/o Password
0-65
Quick Menu Password
0-66
Access to Quick Menu w/o Password
0-67
Bus Password Access
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
[0] English
[0] RPM
[0] International
[1] Forced stop, ref=old
0.0 %
[1] Set-up 1
[1] Set-up 1
[0] Not linked
0 N/A
0 N/A
0 N/A
1617
1614
1610
1613
1602
ExpressionLimit
[0] None
0.00 CustomReadoutUnit
100.00 CustomRea-
doutUnit
0 N/A
0 N/A
0 N/A
null
null
null
null
null
null
[0] No copy
[0] No copy
100 N/A
[0] Full access
200 N/A
[0] Full access
0 N/A
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
1 set-up
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
4
-
Uint8
-
Uint8
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint16
0
Int32
0
Uint8
-
Uint16
-
Uint16
-
Uint16
-
Uint16
-
Uint16
0
Uint16
-
Uint8
-2
Int32
-2
Int32
0
VisStr[25]
0
VisStr[25]
0
VisStr[25]
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
-
Uint8
0
Int16
-
Uint8
0
Uint16
4-5
4