Drive Information - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Lists

4.1.17 15-** Drive Information

Par.
Parameter description
No.
#
15-0* Operating Data
15-00 Operating Hours
15-01 Running Hours
15-02 kWh Counter
15-03 Power-ups
15-04 Over Temps
15-05 Over Volts
15-06 Reset kWh Counter
15-07 Reset Running Hours Counter
15-1* Data Log Settings
15-10 Logging Source
15-11 Logging Interval
15-12 Trigger Event
15-13 Logging Mode
15-14 Samples Before Trigger
15-2* Historic Log
15-20 Historic Log: Event
15-21 Historic Log: Value
15-22 Historic Log: Time
15-3* Fault Log
15-30 Fault Log: Error Code
15-31 Fault Log: Value
15-32 Fault Log: Time
15-4* Drive Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered Typecode String
15-45 Actual Typecode String
15-46 Adj Freq Dr Ordering No.
15-47 Power Card Ordering No.
15-48 LCP ID Num.
15-49 SW ID Control Card
15-50 SW ID Power Card
15-51 Adj Freq Dr Serial No.
15-53 Power Card Serial Number
15-58 Smart Setup Filename
15-59 CSIV Filename
15-6* Option Ident
15-60 Option Mounted
15-61 Option SW Version
15-62 Option Ordering No
15-63 Option Serial No
15-70 Option in Slot A
15-71 Slot A Option SW Version
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
0 h
0 h
0 kWh
0 N/A
0 N/A
0 N/A
[0] Do not reset
[0] Do not reset
0
ExpressionLimit
[0] FALSE
[0] Log always
50 N/A
0 N/A
0 N/A
0 ms
0 N/A
0 N/A
0 s
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion
index
74
Uint32
4
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint16
-3
TimD
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint32
-3
Uint32
0
Uint8
0
Int16
0
Uint32
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[5]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[8]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[10]
0
VisStr[19]
0
VisStr[16]
0
VisStr[16]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[18]
0
VisStr[30]
0
VisStr[20]
4-25
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents