Mco Adv. Settings - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Lists

4.1.23 33-** MCO Adv. Settings

Par.
Parameter description
No.
#
33-0* Home Motion
33-00 Force HOME
33-01 Zero Point Offset from Home Pos.
33-02 Ramp for Home Motion
33-03 Velocity of Home Motion
33-04 Behavior during Home Motion
33-1* Synchronization
33-10 Synchronization Factor Master (M:S)
33-11 Synchronization Factor Slave (M:S)
33-12 Position Offset for Synchronization
33-13 Accuracy Window for Position Sync.
33-14 Relative Slave Velocity Limit
33-15 Marker Number for Master
33-16 Marker Number for Slave
33-17 Master Marker Distance
33-18 Slave Marker Distance
33-19 Master Marker Type
33-20 Slave Marker Type
33-21 Master Marker Tolerance Window
33-22 Slave Marker Tolerance Window
33-23 Start Behavior for Marker Sync
33-24 Marker Number for Fault
33-25 Marker Number for Ready
33-26 Velocity Filter
33-27 Offset Filter Time
33-28 Marker Filter Configuration
33-29 Filter Time for Marker Filter
33-30 Maximum Marker Correction
33-31 Synchronization Type
33-32 Feed Forward Velocity Adaptation
33-33 Velocity Filter Window
33-34 Slave Marker filter time
33-4* Limit Handling
33-40 Behavior at End Limit Switch
33-41 Negative Software End Limit
33-42 Positive Software End Limit
33-43 Negative Software End Limit Active
33-44 Positive Software End Limit Active
33-45 Time in Target Window
33-46 Target Window LimitValue
33-47 Size of Target Window
33-5* I/O Configuration
33-50 Terminal X57/1 Digital Input
33-51 Terminal X57/2 Digital Input
33-52 Terminal X57/3 Digital Input
33-53 Terminal X57/4 Digital Input
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
[0] Home not forced
0 N/A
10 N/A
10 N/A
[0] Reverse and index
1 N/A
1 N/A
0 N/A
1000 N/A
0 %
1 N/A
1 N/A
4096 N/A
4096 N/A
[0] Encoder Z positive
[0] Encoder Z positive
0 N/A
0 N/A
[0] Start Function 1
10 N/A
1 N/A
0 us
0 ms
[0] Marker filter 1
0 ms
0 N/A
[0] Standard
0 N/A
0 N/A
0 ms
[0] Call error handler
-500000 N/A
500000 N/A
[0] Inactive
[0] Inactive
0 ms
1 N/A
0 N/A
[0] No function
[0] No function
[0] No function
[0] No function
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
4
0
Int32
0
Uint32
0
Int32
-
Uint8
0
Int32
0
Int32
0
Int32
0
Int32
0
Uint8
0
Uint16
0
Uint16
0
Uint32
0
Uint32
-
Uint8
-
Uint8
0
Uint32
0
Uint32
-
Uint16
0
Uint16
0
Uint16
-6
Int32
-3
Uint32
-
Uint8
-3
Int32
0
Uint32
-
Uint8
0
Uint32
0
Uint32
-3
Uint32
-
Uint8
0
Int32
0
Int32
-
Uint8
-
Uint8
-3
Uint8
0
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
4-33
4