Special Functions - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Lists

4.1.16 14-** Special Functions

Par.
Parameter description
No.
#
14-0* Inverter Switching
14-00 Switching Pattern
14-01 Switching Frequency
14-03 Overmodulation
14-04 PWM Random
14-06 Dead Time Compensation
14-1* Mains On/Off
14-10 Line Failure
14-11 Line Voltage at Line Fault
14-12 Function at Mains Imbalance
14-13 Line Failure Step Factor
14-14 Kin. Backup Time Out
14-15 Kin. Backup Trip Recovery Level
14-2* Trip Reset
14-20 Reset Mode
14-21 Automatic Restart Time
14-22 Operation Mode
14-23 Typecode Setting
14-24 Trip Delay at Current Limit
14-25 Trip Delay at Torque Limit
14-26 Trip Delay at Inverter Fault
14-28 Production Settings
14-29 Service Code
14-3* Current Limit Ctrl.
14-30 Current Lim Ctrl, Proportional Gain
14-31 Current Lim Ctrl, Integration Time
14-32 Current Lim Ctrl, Filter Time
14-35 Stall Protection
14-4* Energy Optimizing
14-40 VT Level
14-41 AEO Minimum Magnetization
14-42 Minimum AEO Frequency
14-43 Motor Cos-Phi
14-5* Environment
14-50 RFI 1
14-51 DC Link Compensation
14-52 Fan Control
14-53 Fan Monitor
14-55 Output Filter
14-56 Capacitance Output Filter
14-57 Inductance Output Filter
14-59 Actual Number of Inverter Units
14-7* Compatibility
14-72 VLT Alarm Word
14-73 VLT Warning Word
14-74 VLT Ext. Status Word
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
null
null
[1] On
[0] Off
[1] On
[0] No function
ExpressionLimit
[0] Trip
1.0 N/A
60 s
ExpressionLimit
[0] Manual reset
ExpressionLimit
[0] Normal operation
null
60 s
60 s
ExpressionLimit
[0] No action
0 N/A
100 %
0.020 s
1.0 ms
[1] Enabled
66 %
ExpressionLimit
10 Hz
ExpressionLimit
[1] On
[1] On
[0] Auto
[1] Warning
[0] No Filter
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
x
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
x
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion
index
-
Uint8
4
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-1
Uint8
0
Uint8
-3
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Int32
0
Uint16
-3
Uint16
-4
Uint16
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-7
Uint16
-6
Uint16
0
Uint8
0
Uint32
0
Uint32
0
Uint32
4-23
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents