Danfoss VLT AutomationDrive Programming Manual page 77

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Descriptions
Preset ramp bit
Ramp 1
Ramp 2
Ramp 3
3
3
Ramp 4
[40]
Latched
Precise Start
[41]
Latched
Precise Stop
inverse
[51]
External
interlock
[55]
DigiPot
Increase
[56]
DigiPot
Decrease
[57]
DigiPot Clear
[60]
Counter A
[61]
Counter A
[62]
Reset
Counter A
[63]
Counter B
[64]
Counter B
[65]
Reset
Counter B
[70]
Mech. Brake
Feedback
[71]
Mech. Brake
Feedback inv.
[72]
PID error
inverse
3-52
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
1
0
0
1
1
A latched precise start only requires a pulse
of 3ms on T18 or T19.
When using for 1-83 [1] or [2]:
When the reference is reached, the
Adjustable frequency drive will internally
enable the Precise Stop signal. This means
that the Adjustable frequency drive will do
the Precise Stop when the counter value of
1-84 Precise Stop Counter Value is reached.
Sends a latched stop signal when the
precise stop function is activated in
1-83 Precise Stop Function. The latched
precise stop inverse function is available for
terminals 18 or 19.
This function makes it possible to give an
external fault to the drive. This fault is
treated in the same way as an internally
generated alarm.
INCREASE signal to the digital potenti-
ometer function described in parameter
group 3-9*.
DECREASE signal to the digital potenti-
ometer function described in parameter
group 3-9*.
Clears the digital potentiometer reference
described in parameter group 3-9*.
(Terminal 29 or 33 only) Input for
increment counting in the SLC counter.
(Terminal 29 or 33 only) Input for
decrement counting in the SLC counter.
Input for reset of counter A.
(Terminal 29 or 33 only) Input for
increment counting in the SLC counter.
(Terminal 29 or 33 only) Input for
decrement counting in the SLC counter.
Input for reset of counter B.
Brake feedback for hoisting applications:
Set 1-01 Motor Control Principle to [3] flux
w/ motor feedback; set 1-72 Start Function to
[6] Hoist mech brake Ref.
Inverted brake feedback for hoisting
applications
When enabled, it inverts the resulting error
from the process PID controller. Available
only if "Configuration Mode" is set to
MG33MD22 - VLT
0
0
[73]
PID reset I-
1
part
0
1
[74]
PID enable
[80]
PTC Card 1
[91]
Profidrive
OFF2
[92]
Profidrive
OFF3
[98]
Start edge
triggered
[100] Safe Option
Reset
5-10 Terminal 18 Digital Input
Option:
Function:
[8]
Start Functions are described under 5-1* Digital Inputs
*
5-11 Terminal 19 Digital Input
Option:
[10]
Reversing Functions are described under 5-1* Digital
*
5-12 Terminal 27 Digital Input
Option:
[2]
Coast inverse Functions are described under parameter
*
5-13 Terminal 29 Digital Input
Option:
Function:
Select the function from the available digital input
range and the additional options [60], [61], [63] and
[64]. Counters are used in Smart Logic Control
functions.This parameter is available for FC 302 only.
[14]
Jog Functions are described under 5-1* Digital Inputs
*
®
is a registered Danfoss trademark
"Surface Winder," "Extended PID Speed OL"
or "Extended PID Speed CL."
When enabled, resets the I-part of the
process PID controller. Equivalent to
7-40 Process PID I-part Reset. Available only
if "Configuration Mode" is set to "Surface
Winder," "Extended PID Speed OL" or
"Extended PID Speed CL."
When enabled, enables the extended
process PID controller. Equivalent to
7-50 Process PID Extended PID. Available only
if "Configuration Mode" is set "Extended
PID Speed OL" or "Extended PID Speed CL."
All digital inputs can be set to PTC card 1
[80]. However, only one digital input must
be set to this choice.
The functionality is the same as the
according control word bit of the Profibus/
Profinet option.
The functionality is the same as the
according control word bit of the Profibus/
Profinet option.
Edge triggered start command. Keeps the
start command alive, even if the input is
going back to low; can be used for a start
push button.
Function:
Inputs
Function:
group 5-1* Digital Inputs