Parameter Descriptions
13-15 RS-FF Operand S
Option:
[29]
Logic rule 3
3
3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
[45]
Left key
[46]
Right key
[47]
Up key
[48]
Down key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
[75]
Start command given
[76]
Digital input x30/2
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning
[91]
ATEX ETR cur. alarm
[92]
ATEX ETR freq. warning
[93]
ATEX ETR freq. alarm
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
3-118
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
13-15 RS-FF Operand S
Function:
Option:
[99]
[100]
[101]

13-16 RS-FF Operand R

Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
[35]
[36]
[37]
[38]
[39]
[40]
[41]
[42]
®
MG33MD22 - VLT
is a registered Danfoss trademark
RS Flipflop 5
RS Flipflop 6
RS Flipflop 7
False
True
Running
In range
On reference
Torque limit
Current limit
Out of current range
Below I low
Above I high
Out of speed range
Below speed low
Above speed high
Out of feedb. range
Below feedb. low
Above feedb. high
Thermal warning
Mains out of range
Reversing
Warning
Alarm (trip)
Alarm (trip lock)
Comparator 0
Comparator 1
Comparator 2
Comparator 3
Logic rule 0
Logic rule 1
Logic rule 2
Logic rule 3
SL Time-out 0
SL Time-out 1
SL Time-out 2
Digital input DI18
Digital input DI19
Digital input DI27
Digital input DI29
Digital input DI32
Digital input DI33
Start command
Drive stopped
Reset Trip
Auto-reset Trip
Function:
Function: