Parameter Descriptions
8-13 Configurable Status Word STW
Option:
Function:
[71] Logic Rule 1
If Logic Rule 1 is evaluated as TRUE, the
input will go high. Otherwise, it will be
low.
[72] Logic Rule 2
If Logic Rule 2 is evaluated as TRUE, the
input will go high. Otherwise, it will be
low.
[73] Logic Rule 3
If Logic Rule 3 is evaluated as TRUE, the
input will go high. Otherwise, it will be
low.
[74] Logic Rule 4
If Logic Rule 4 is evaluated as TRUE, the
input will go high. Otherwise, it will be
low.
[75] Logic Rule 5
If Logic Rule 5 is evaluated as TRUE, the
input will go high. Otherwise, it will be
low.
[80] SL digital out A SL Controller Action. The input will go
high whenever the Smart Logic Action
[38] Set dig. out. A high is executed. The
input will go low whenever the Smart
Logic Action [32] Set dig. out. A low is
executed.
[81] SL digital out B SL Controller Action. The input will go
high whenever the Smart Logic Action
[39] Set dig. out. A high is executed. The
input will go low whenever the Smart
Logic Action [33] Set dig. out. A low is
executed.
[82] SL digital out C SL Controller Action. The input will go
high whenever the Smart Logic Action
[40] Set dig. out. A high is executed. The
input will go low whenever the Smart
Logic Action [34] Set dig. out. A low is
executed.
[83] SL digital out D SL Controller Action. The input will go
high whenever the Smart Logic Action
[41] Set dig. out. A high is executed. The
input will go low whenever the Smart
Logic Action [35] Set dig. out. A low is
executed.
[84] SL digital out E
SL Controller Action. The input will go
high whenever the Smart Logic Action
[42] Set dig. out. A high is executed. The
input will go low whenever the Smart
Logic Action [36] Set dig. out. A low is
executed.
[85] SL digital out F
SL Controller Action. The input will go
high whenever the Smart Logic Action
[43] Set dig. out. A high is executed. The
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
8-13 Configurable Status Word STW
Option:
[86] ATEX ETR cur.
[87] ATEX ETR freq.
[88] ATEX ETR cur.
[89] ATEX ETR freq.
[90] Safe Function
[91] Safe Opt. Reset

8-14 Configurable Control Word CTW

Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
®
MG33MD22 - VLT
is a registered Danfoss trademark
Function:
input will go low whenever the Smart
Logic Action [37] Set dig. out. A low is
executed
Selectable if par. 1-90 is set to [20] or [21].
alarm
If the alarm 164 ATEX ETR cur.lim.alarm is
active, the output will be 1.
Selectable if par. 1-90 is set to [20] or [21].
alarm
If the alarm 166 ATEX ETR freq.lim.alarm is
active, the output will be 1.
Selectable if par. 1-90 is set to [20] or [21].
warning
If the alarm 163 ATEX ETR cur.lim.warning
is active, the output will be 1.
Selectable if par. 1-90 is set to [20] or [21].
warning
If the warning 165 ATEX ETR
freq.lim.warning is active, the output will
be 1.
active
req.
Function:
Selection of control word bit 10 if it is active
low or active high
None
Profile
*
default
CTW Valid,
active low
Safe Option
Reset
PID error
When enabled, it inverts the resulting error
inverse
from the process PID controller. Available
only if "Configuration Mode" is set to
"Surface Winder," "Extended PID Speed OL"
or "Extended PID Speed CL."
PID reset I
When enabled, resets the I-part of the
part
process PID controller. Equivalent to
7-40 Process PID I-part Reset. Available only if
"Configuration Mode" is set to "Surface
Winder," "Extended PID Speed OL" or
"Extended PID Speed CL."
PID enable
When enabled, enables the extended
process PID controller. Equivalent to
7-50 Process PID Extended PID. Available only
if "Configuration Mode" is set "Extended PID
Speed OL" or "Extended PID Speed CL."