Parameter Descriptions

4-57 Warning Feedback High

Range:
999999.999
3
3
ReferenceFeed-
backUnit
*

4-58 Missing Motor Phase Function

Displays an alarm in the event of a missing motor phase (alarm
30, 31 or 32). Select disabled for no missing motor phase alarm.
It is strongly recommended to make an active setting to avoid
motor damage.
Option:
[0]
*
[1]
[2]
[3]
NOTE!
This parameter cannot be adjusted while the motor is
running.

3.6.4 4-6* Speed Bypass

Some systems call for avoiding certain output frequencies
or speeds due to resonance problems in the system. A
maximum of four frequency or speed ranges can be
avoided.
4-60 Bypass Speed From [RPM]
Array [4]
Range:
Application
dependent
*
3-48
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
Function:
[Application
Enter the upper feedback
dependant]
limit. When the feedback
exceeds this limit, the display
reads Feedb High. The signal
outputs can be programmed
to produce a status signal on
terminal 27 or 29 (FC 302
only) and on relay output 01
or 02 (FC 302 only).
Function:
Disabled
No alarm is displayed if a
missing motor phase
occurs.
Trip 100 ms
Trips after 100 ms. Select
100ms for fast detection of
missing motor phase.
Trip 1000 ms
Trips after 1000ms. Select
1000ms for slow detection
of missing motor phase.
Trip 100ms 3ph
detec.
Function:
[Application
Some systems call for
dependant]
avoiding certain output
speeds due to resonance
problems in the system.
Enter the lower limits of the
speeds to be avoided.
MG33MD22 - VLT
FC 300 Programming Guide
4-61 Bypass Speed From [Hz]
Array [4]
Range:
Size related
4-62 Bypass Speed To [RPM]
Array [4]
Range:
Application
dependent
4-63 Bypass Speed To [Hz]
Array [4]
Range:
Application
dependent
®
is a registered Danfoss trademark
[ 0.0 - par. 4-14 Hz]
*
Function:
[Application
Some systems call for
dependant]
avoiding certain output
*
speeds due to resonance
problems in the system.
Enter the upper limits of
the speeds to be avoided.
Function:
[Application
Some systems call for
dependant]
avoiding certain output
*
speeds due to resonance
problems in the system.
Enter the upper limits of
the speeds to be avoided.