4.1.8 5-** Digital In/Out
Par.
Parameter description
No.
#
5-0* Digital I/O mode
5-00
Digital I/O Mode
4
4
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-19
Terminal 37 Safe Stop
5-20
Terminal X46/1 Digital Input
5-21
Terminal X46/3 Digital Input
5-22
Terminal X46/5 Digital Input
5-23
Terminal X46/7 Digital Input
5-24
Terminal X46/9 Digital Input
5-25
Terminal X46/11 Digital Input
5-26
Terminal X46/13 Digital Input
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 digital Output
5-32
Term X30/6 Digi Out (MCB 101)
5-33
Term X30/7 Digi Out (MCB 101)
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
4-12
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
[0] PNP
[0] Input
[0] Input
null
null
null
null
null
null
null
null
null
null
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
null
null
null
null
null
0.01 s
0.01 s
100 Hz
100 Hz
0.000 ReferenceFeed-
backUnit
ExpressionLimit
100 ms
100 Hz
100 Hz
0.000 ReferenceFeed-
backUnit
ExpressionLimit
100 ms
null
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
x
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
-
Uint8