Data Readouts - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Lists

4.1.18 16-** Data Readouts

Par.
Parameter description
No.
#
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
16-02 Reference %
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor voltage
16-13 Frequency
16-14 Motor Current
16-15 Frequency [%]
16-16 Torque [Nm]
16-17 Speed [RPM]
16-18 Motor Thermal
16-19 KTY sensor temperature
16-20 Motor Angle
16-21 Torque [%] High Res.
16-22 Torque [%]
16-25 Torque [Nm] High
16-3* Drive Status
16-30 DC Link Voltage
16-32 Brake Energy /s
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-41 LCP Bottom Statusline
16-49 Current Fault Source
16-5* Ref. & Feedb.
16-50 External Reference
16-51 Pulse Reference
16-52 Feedback [Unit]
16-53 Digi Pot Reference
16-57 Feedback [RPM]
16-6* Inputs & Outputs
16-60 Digital Input
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
0 N/A
0.000 ReferenceFeed-
backUnit
0.0 %
0 N/A
0.00 %
0.00 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.00 %
0.0 Nm
0 RPM
0 %
0 °C
0 N/A
0.0 %
0 %
0.0 Nm
0 V
0.000 kW
0.000 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
0 N/A
0 N/A
0.0 N/A
0.0 N/A
0.000 ReferenceFeed-
backUnit
0.00 N/A
0 RPM
0 N/A
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion
index
0
V2
4
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int16
67
Int32
0
Uint8
100
Int16
0
Uint16
-1
Int16
0
Int16
-1
Int32
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
-
Uint8
VisStr[5
0
0]
0
Uint8
-1
Int16
-1
Int16
-3
Int32
-2
Int16
67
Int32
0
Uint16
4-27
4