Comparator Operator - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Descriptions
13-10 Comparator Operand
Array [6]
Option:
3
3
[151] SL digital output
B
[152] SL digital output
C
[153] SL digital output
D
[154] SL digital output
E
[155] SL digital output
F
[160] Relay 1
[161] Relay 2
[180] Local ref. active
[181] Remote ref.
active
[182] Start command
[183] Drive stopped
[185] Drive in hand
mode
[186] Drive in auto
mode
[187] Start command
given
[190] Digital input x30
2
[191] Digital input x30
3
[192] Digital input x30
4
[193] Digital input x46
1
[194] Digital input x46
2
3-116
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Function:
SL digital output B [151] Use the result of
the SLC output B.
SL digital output C [152] Use the result
of the SLC output C.
SL digital output D [153] Use the result
of the SLC output D.
SL digital output E [154] Use the result of
the SLC output E.
SL digital output F [155] Use the result of
the SLC output F.
Relay 1 [160] Relay 1 is active
Relay 2 [161] Relay 2 is active
Local ref. active [180] High when
3-13 Reference Site = [2] Local or when
3-13 Reference Site is [0] Linked to hand
auto, at the same time as the LCP is in
hand on mode.
Remote ref. active [181] High when
3-13 Reference Site= [1] Remote or [0]
Linked to hand/auto, while the LCP is in
auto on mode.
Start command [182] High when there is
an active start command and no stop
command.
Drive stopped [183] A stop command
(Jog, Stop, Qstop, Coast) is issued – and
not from the SLC itself.
Drive in hand mode [185] High when the
Adjustable frequency drive is in hand
mode.
Drive in auto mode [186] High when the
Adjustable frequency drive is in auto
mode.
MG33MD22 - VLT
13-10 Comparator Operand
Array [6]
Option:
[195] Digital input x46
3
[196] Digital input x46
4
[197] Digital input x46
5
[198] Digital input x46
6
[199] Digital input x46
7

13-11 Comparator Operator

Array [6]
Option:
Function:
Select the operator to be used in the
comparison. This is an array parameter
containing comparator operators 0 to 5.
[0]
<
Select < [0] for the result of the evaluation to
be TRUE, when the variable selected in
13-10 Comparator Operand is smaller than the
fixed value in 13-12 Comparator Value. The
result will be FALSE, if the variable selected in
13-10 Comparator Operand is greater than the
fixed value in 13-12 Comparator Value.
[1]
≈ (equal)
Select ≈ [1] for the result of the evaluation to
*
be TRUE, when the variable selected in
13-10 Comparator Operand is approximately
equal to the fixed value in 13-12 Comparator
Value.
[2]
>
Select > [2] for the inverse logic of option <
[0].
[5]
TRUE longer
than..
[6]
FALSE
longer
than..
[7]
TRUE
shorter
than..
[8]
FALSE
shorter
than..
®
is a registered Danfoss trademark
Function:

Hide quick links:

Advertisement

Table of Contents
loading