0-37 Display Text 1
Range:
0
[0 - 0 ] Enter a text which can be viewed in the graphical
*
3
3
display by selecting Display Text 1 [37] in
0-20 Display Line 1.1 Small, 0-21 Display Line 1.2
Small, 0-22 Display Line 1.3 Small, 0-23 Display Line 2
Large or 0-24 Display Line 3 Large.
0-38 Display Text 2
Range:
0
[0 - 0 ] Enter a text which can be viewed in the graphical
*
display by selecting Display Text 2 [38] in
0-20 Display Line 1.1 Small, 0-21 Display Line 1.2
Small, 0-22 Display Line 1.3 Small, 0-23 Display Line 2
Large or 0-24 Display Line 3 Large.
0-39 Display Text 3
Range:
0
[0 - 0 ] Enter a text which can be viewed in the graphical
*
display by selecting Display Text 3 [39] in
0-20 Display Line 1.1 Small, 0-21 Display Line 1.2
Small, 0-22 Display Line 1.3 Small, 0-23 Display Line 2
Large or 0-24 Display Line 3 Large.

3.2.5 0-4* LCP Keypad

Enable, disable and password protect individual keys on
the LCP.

0-40 [Hand on] Key on LCP

Option:
[0]
Disabled
*
[1]
Enabled
*
[2]
Password
[3]
Hand Off/On
[4]
Hand Off/On
w. Passw.
[9]
Enabled, ref =
0
3-10
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
Function:
Function:
Function:
Function:
No effect when [Hand on] is pressed.
Select [0] Disabled to avoid accidental
start of the Adjustable frequency drive in
Hand on mode.
The LCP switches to Hand on mode
directly when [Hand on] is pressed.
After pressing [Hand on], a password is
required. If 0-40 [Hand on] Key on LCP is
included in My Personal Menu, define the
password in 0-65 Quick Menu Password.
Otherwise, define the password in
0-60 Main Menu Password.
When [Hand on] is pressed once, the LCP
switches to Off mode. When pressed
again, the LCP switches to Hand on mode.
Same as [3] but a password is required
(see [2]).
MG33MD22 - VLT
FC 300 Programming Guide
0-41 [Off] Key on LCP
Option:
[0]
Disabled
*
[1]
Enabled
*
[2]
Password Avoids unauthorized stop. If 0-41 [Off] Key on LCP
0-42 [Auto on] Key on LCP
Option:
[0]
Disabled
*
[1]
Enabled
*
[2]
Password Avoids unauthorized start in auto mode. If

0-43 [Reset] Key on LCP

Option:
[0]
Disabled
*
[1]
Enabled
*
[2]
Password
[7]
Enabled
without OFF
[8]
Password
without OFF

3.2.6 0-5* Copy/Save

Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option:
[0]
No copy
*
[1]
All to LCP
[2]
All from LCP
®
is a registered Danfoss trademark
Function:
Avoids accidental stop of the Adjustable
frequency drive.
is included in the Quick Menu, then define the
password in 0-65 Quick Menu Password.
Function:
Avoid accidental start of the Adjustable
frequency drive in auto mode.
0-42 [Auto on] Key on LCP is included in the
Quick Menu, then define the password in
0-65 Quick Menu Password.
Function:
No effect when [Reset] is pressed. Avoids
accidental alarm reset.
Avoids unauthorized resetting. If
0-43 [Reset] Key on LCP is included in the
Quick Menu, then define the password in
0-65 Quick Menu Password.
Resets the Adjustable frequency drive
without setting it in Off mode.
Resets the Adjustable frequency drive
without setting it in Off mode. A password
is required when pressing [Reset] (see [2]).
Function:
Copies all parameters in all set-ups
from the Adjustable frequency drive
memory to the LCP memory.
Copies all parameters in all set-ups
from the LCP memory to the
Adjustable frequency drive memory.