Sensor Input Option - Danfoss VLT AutomationDrive Programming Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

Parameter Lists

4.1.25 35-** Sensor Input Option

Par.
Parameter description
No.
#
35-0* Temp. Input Mode
35-00 Term. X48/4 Temp. Unit
4
4
35-01 Term. X48/4 Input Type
35-02 Term. X48/7 Temp. Unit
35-03 Term. X48/7 Input Type
35-04 Term. X48/10 Temp. Unit
35-05 Term. X48/10 Input Type
35-06 Temperature Sensor Alarm Function
35-1* Temp. Input X48/4
35-14 Term. X48/4 Filter Time Constant
35-15 Term. X48/4 Temp. Monitor
35-16 Term. X48/4 Low Temp. Limit
35-17 Term. X48/4 High Temp. Limit
35-2* Temp. Input X48/7
35-24 Term. X48/7 Filter Time Constant
35-25 Term. X48/7 Temp. Monitor
35-26 Term. X48/7 Low Temp. Limit
35-27 Term. X48/7 High Temp. Limit
35-3* Temp. Input X48/10
35-34 Term. X48/10 Filter Time Constant
35-35 Term. X48/10 Temp. Monitor
35-36 Term. X48/10 Low Temp. Limit
35-37 Term. X48/10 High Temp. Limit
35-4* Analog Input X48/2
35-42 Term. X48/2 Low Current
35-43 Term. X48/2 High Current
35-44 Term. X48/2 Low Ref./Feedb. Value
35-45 Term. X48/2 High Ref./Feedb. Value
35-46 Term. X48/2 Filter Time Constant
4-36
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[5] Stop and trip
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
4.00 mA
All set-ups
20.00 mA
All set-ups
0.000 N/A
All set-ups
100.000 N/A
All set-ups
0.001 s
All set-ups
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16