Parameter Descriptions
3.13.4 12-3* EtherNet/IP
12-30 Warning parameter
Range:
Function:
[0000–
Read only. Displays the EtherNet/IP specific 16-bit
FFFF hex]
status word.
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
12-31 Net Reference
Option:
Function:
Read only. Displays the reference source in Instance
21/71.
[0]
Off Reference from the network is not active.
*
[1]
On Reference from the network is active.
12-32 Net Control
Option:
Function:
Read only. Displays the control source in Instance
21/71.
[0]
Off Control via the network is not active.
*
[1]
On Control via the network is active
12-33 CIP Revision
Option:
Read only. Displays the CIP version of
the option software.
[0] Major version (00–99)
[1] Minor version (00–99)
12-34 CIP Product Code
Range:
1100 (FC 302) 1110
[0 – 9999] Read only. Displays the CIP
(FC 301)
*
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Description
Owned
Not used
Configured
Not used
Not used
Not used
Not used
Not used
Minor recoverable fault
Minor unrecoverable fault
Major recoverable fault
Major unrecoverable fault
Not used
Not used
Not used
Not used
Function:
Function:
product code.
®
MG33MD22 - VLT
is a registered Danfoss trademark
12-37 COS Inhibit Timer
Range:
Function:
[0–65.535
Read-only Change-Of-State inhibit timer. If the
ms]
option is configured for COS operation, this
inhibit timer can be configured in the Forward
Open message to prevent that continuously
changing PCD data generates extensive network
traffic. The inhibit time is in milliseconds, 0 =
disabled.
12-38 COS Filters
Range:
Function:
[[0–9] Filter 0–9
Change-Of-State PCD filters. Sets up a
(0000–FFFFhex)]
filter mask for each word of process data
when operating in COS mode. Single bits
in the PCDs can be filtered in/out.
12-50 Configured Station Alias
Range:
Function:
0
[0 - 65535 ] The parameter shows the configured EtherCAT
*
station alias for the Adjustable frequency drive.
Changes will first be active after a power cycle.
12-51 Configured Station Address
Range:
Function:
0
[0 - 65535 ] The parameter shows the configured station
*
address. The parameter can only be set by the
master at power-up.
12-59 EtherCAT Status
Range:
Function:
0
[0 - 4294967295 ] This parameter contains status
*
information on the EtherCAT interface.
Refer to the EtherCAT manual for
detailed information.
12-80 FTP Server
Option:
Function:
[0]
Disable
Disables the built-in FTP server.
*
[1]
Enable
Enables the built-in FTP server.
12-81 HTTP Server
Option:
Function:
[0]
Disable
Disables the built-in HTTP (web) server.
*
[1]
Enable
Enables the built-in HTTP (web) server.
12-82 SMTP Service
Option:
Function:
[0]
Disable Disables the SMTP (e-mail) service on the option.
*
[1]
Enable
Enables the SMTP (e-mail) service on the option.
3
3
3-107