How to Program
Q3-40 Fan Functions
22-60 Broken Belt Function
22-61 Broken Belt Torque
22-62 Broken Belt Delay
4-64 Semi-Auto Bypass Set-up
1-03 Torque Characteristics
22-22 Low Speed Detection
22-23 No-Flow Function
22-24 No-Flow Delay
22-40 Minimum Run Time
22-41 Minimum Sleep Time
22-42 Wake-up Speed [RPM]
22-43 Wake-up Speed [Hz]
22-44 Wake-up Ref./FB Difference
22-45 Setpoint Boost
22-46 Maximum Boost Time
2-10 Brake Function
2-16 AC Brake Max. Current
2-17 Over-voltage Control
1-73 Flying Start
1-71 Start Delay
1-80 Function at Stop
2-00 DC Hold/Preheat Current
4-10 Motor Speed Direction
Table 2.6

2.1.7 Main Menu Mode

Select main menu mode by pressing the [Main Menu] key.
The readout below appears on the display.
The middle and bottom sections on the display show a list
of parameter groups which can be chosen by toggling the
up and down buttons.
1107 RPM
Main Menu
0 - ** Operation/Display
1 - ** Load/Motor
2 - ** Brakes
3 - ** Reference / Ramps
Figure 2.24
®
VLT
HVAC Drive Programming Guide
Q3-4 Application Settings
Q3-41 Pump Functions
22-20 Low Power Auto Set-up
22-21 Low Power Detection
22-22 Low Speed Detection
22-23 No-Flow Function
22-24 No-Flow Delay
22-40 Minimum Run Time
22-41 Minimum Sleep Time
22-42 Wake-up Speed [RPM]
22-43 Wake-up Speed [Hz]
22-44 Wake-up Ref./FB Difference
22-45 Setpoint Boost
22-46 Maximum Boost Time
22-26 Dry Pump Function
22-27 Dry Pump Delay
22-80 Flow Compensation
22-81 Square-linear Curve Approximation
22-82 Work Point Calculation
22-83 Speed at No-Flow [RPM]
22-84 Speed at No-Flow [Hz]
22-85 Speed at Design Point [RPM]
22-86 Speed at Design Point [Hz]
22-87 Pressure at No-Flow Speed
22-88 Pressure at Rated Speed
22-89 Flow at Design Point
22-90 Flow at Rated Speed
1-03 Torque Characteristics
1-73 Flying Start
Each parameter has a name and number which remain the
same regardless of the programming mode. In main menu
mode, the parameters are divided into groups. The first
digit of the parameter number (from the left) indicates the
parameter group number.
All parameters can be changed in the Main Menu.
3.84 A
1 (1)
However, depending on the choice of configuration
(1-00 Configuration Mode), some parameters can be hidden.
2.1.8 Parameter Selection
In main menu mode, the parameters are divided into
groups. You select a parameter group by means of the
navigation keys.
MG11CD22 - VLT
®
is a registered Danfoss trademark
Q3-42 Compressor Functions
1-03 Torque Characteristics
1-71 Start Delay
22-75 Short Cycle Protection
22-76 Interval between Starts
22-77 Minimum Run Time
5-01 Terminal 27 Mode
5-02 Terminal 29 Mode
5-12 Terminal 27 Digital Input
5-13 Terminal 29 Digital Input
5-40 Function Relay
1-73 Flying Start
1-86 Trip Speed Low [RPM]
1-87 Trip Speed Low [Hz]
2
2
2-13