Parameter Descriptions
16-16 Torque [Nm]
Range:
3
3
16-17 Speed [RPM]
Range:
0 RPM
[-30000 -
*
30000 RPM]
16-18 Motor Thermal
Range:
0 %
[0 - 100 %] View the calculated thermal load on the
*
16-19 KTY sensor temperature
Range:
0 C
*
16-20 Motor Angle
Range:
0
[0 - 65535 ] View the current encoder/resolver angle offset
*
16-21 Torque [%] High Res.
Range:
0.0 %
*
16-22 Torque [%]
Range:
0 %
[-200 - 200 %] Value shown is the torque as a
*

16-25 Torque [Nm] High

Range:
0.0
[-200000000.0 -
Nm
200000000.0 Nm]
*
3-142
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
Function:
from when an input changes value to when
the data readout values change.
Function:
View the actual motor RPM. In open-
loop or closed-loop process control, the
motor RPM is estimated. In speed
closed-loop modes, the motor RPM is
measured.
Function:
motor. The cut-out limit is 100%. The basis
for calculation is the ETR function selected in
1-90 Motor Thermal Protection.
Function:
[0 - 0 C]
Function:
relative to the index position. The value range
of 0-65535 corresponds to 0-2*pi (radians).
[-200.0 - 200.0 %]
Function:
percentage of nominal torque, with sign,
applied to the motor shaft.
Function:
View the torque value with sign,
applied to the motor shaft. Some
motors supply more than 160%
torque. Consequently, the min. value
and the max. value will depend on
the max. motor current as well as the
motor used. This specific readout has
been adapted to show higher values
than the standard readout in
16-16 Torque [Nm].
MG33MD22 - VLT
FC 300 Programming Guide

3.17.2 16-3* Drive Status

16-30 DC Link Voltage
Range:
0 V
[0 - 10000 V] View a measured value. The value is filtered
*
16-32 Brake Energy /s
Range:
0.000 kW
16-33 Brake Energy /2 min
Range:
0.000 kW
16-34 Heatsink Temp.
Range:
0 °C
*
16-35 Inverter Thermal
Range:
0 %
*

16-36 Inv. Nom. Current

Function:
Range:
Application
dependent
Application
dependent

16-37 Inv. Max. Current

Range:
Application
dependent
®
is a registered Danfoss trademark
Function:
with an 30ms time constant.
Function:
[0.000 - 10000.000
View the braking energy
*
kW]
transmitted to an external brake
resistor, stated as an instan-
taneous value.
Function:
[0.000 -
View the braking energy
*
10000.000 kW]
transmitted to an external brake
resistor. The mean power is
calculated on an average basis for
the most recent 120 sec.
[0 - 255 °C]
Function:
[0 - 100 %]
View the percentage load on the inverter.
Function:
[0.01 -
View the inverter nominal
10000.00 A]
current, which should match the
*
nameplate data on the
connected motor. The data are
used for calculation of torque,
motor protection, etc.
[0.01 -
View the inverter nominal
10000.00 A]
current, which should match the
*
nameplate data on the
connected motor. The data are
used for calculation of torque,
motor protection, etc.
Function:
[0.01 -
View the inverter maximum
10000.00 A]
current, which should match the
*
nameplate data on the
Function:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents