Parameter Lists
4.1.9 6-** Analog In/Out
Par.
Parameter description
No.
#
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
4
4
6-01
Live Zero Timeout Function
6-1* Analog Input 1
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-2* Analog Input 2
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-3* Analog Input 53
6-30
Terminal X30/11 Low Voltage
6-31
Terminal X30/11 High Voltage
6-34
Term. X30/11 Low Ref./Feedb. Value
6-35
Term. X30/11 High Ref./Feedb. Value
6-36
Term. X30/11 Filter Time Constant
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
6-44
Term. X30/12 Low Ref./Feedb. Value
6-45
Term. X30/12 High Ref./Feedb. Value
6-46
Term. X30/12 Filter Time Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
6-53
Terminal 42 Output Bus Control
6-54
Terminal 42 Output Timeout Preset
6-55
Terminal 42 Output Filter
6-6* Analog Output 2
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
6-63
Terminal X30/8 Bus Control
6-64
Terminal X30/8 Output Timeout Preset
6-7* Analog Output 3
6-70
Terminal X45/1 Output
4-14
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx
FC 300 Programming Guide
Default value
10 s
[0] Off
0.07 V
10.00 V
0.14 mA
20.00 mA
0 ReferenceFeedbackUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0.14 mA
20.00 mA
0 ReferenceFeedbackUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0 ReferenceFeedbackUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0 ReferenceFeedbackUnit
ExpressionLimit
0.001 s
null
0.00 %
100.00 %
0.00 %
0.00 %
[0] Off
null
0.00 %
100.00 %
0.00 %
0.00 %
null
®
MG33MD22 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
0
Uint8
-
Uint8
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8