Main Menu Mode; Parameter Selection - Danfoss VLT AutomationDrive FC 302 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

How to Programme
Another easy way of commissioning the frequency
converter is by using the Smart Application Setup (SAS),
which can also be found under the Quick Menu. Follow
the indications on the successive screens for setting up the
applications listed.
[Info] can be used throughout the SAS to see help
information for various selections, settings, and messages.
The following 3 applications are included:
Mechanical Brake
Conveyor
Pump/Fan
The following 4 field-busses can be selected:
Profibus
Profinet
DeviceNet
EthernetIP
NOTICE
The start conditions are ignored while in the wizard.
NOTICE
The Smart Set-up runs automatically on the first power-
up of the frequency converter or after a reset to factory
settings. If no action is taken, the SAS screen automat-
ically disappears after 10 min.

2.1.8 Main Menu Mode

Start the Main Menu mode by pressing [Main Menu]. The
read-out shown below appears on the display.
The middle and bottom sections on the display show a list
of parameter groups which can be selected by toggling [
and [
] keys.
1107 RPM
Main menu
0 - ** Operation/Display
1 - ** Load/Motor
2 - ** Brakes
3 - ** Reference / Ramps
Illustration 2.14 Main Menu Mode
Each parameter has a name and number which remain the
same regardless of the programming mode. In the Main
Menu mode, the parameters are divided into groups. The
first digit of the parameter number (from the left) indicates
the parameter group number.
®
VLT
AutomationDrive FC 301/302 Programming Guide
All parameters can be changed in the Main Menu.
However, depending on the choice of configuration
(parameter 1-00 Configuration Mode), some parameters can
be "missing". E.g. open loop hides all the PID parameters,
and other enabled options make more parameter groups
visible.

2.1.9 Parameter Selection

In the Main menu mode, the parameters are divided into
groups. Select a parameter group with the navigation keys.
The following parameter groups are accessible:
Group no. Parameter group
0-**
1-**
2-**
3-**
4-**
5-**
6-**
7-**
8-**
9-**
10-**
11-**
12-**
13-**
14-**
15-**
16-**
17-**
18-**
30-**
32-**
]
33-**
34-**
35-**
3.84 A
1 (1)
Table 2.4 Accessible Parameter Goups
After selecting a parameter group, select a parameter with
the navigation keys.
The middle section on the display shows the parameter
number and name as well as the selected parameter value.
Illustration 2.15 Parameter Selection
MG33MI02 - Rev. 2013-11-20
Operation/Display
Load/Motor
Brakes
References/Ramps
Limits/Warnings
Digital In/Out
Analog In/Out
Controls
Comm. and Options
Profibus
CAN Fieldbus
Reserved Com. 1
Ethernet
Smart Logic
Special Functions
Drive Information
Data Readouts
Motor Feedb. Option
Data Readouts 2
Special Features
MCO Basic Settings
MCO Adv. Settings
MCO Data Readouts
Sensor Input Option
740RPM
Basic Settings
0 -01 Language
[0] English
2
10.64A
1 [1]
0-0 *
19
2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents

Save PDF