Example 11-6. Show Power Command - Compaq AlphaServer DS20E Reference Manual

Hide thumbs Also See for AlphaServer DS20E:
Table of Contents

Advertisement

P00>>> show power
Power Supply 0
Power Supply 1/Fan Tray
System Fans
CPU Fans
Temperature
Current ambient temperature is 27 degrees C
System shutdown temperature is set to 55 degrees C
2 Environmental events are logged in nvram
Do you want to view the events? (Y/<N>) y
Total Environmental Events: 2 (2 logged)
1
000
0
2
000
0
Do you want to clear all events from nvram? (Y/<N>) y
P00>>>

Example 11-6. Show Power Command

The show power command displays status information about the power
supplies, system fans, CPU fans, and temperature. This command is useful for
displaying the error state of a Tru64 UNIX or OpenVMS system that shuts
down because of a fan, temperature, or power supply failure. If the system can
be restarted, use this command. (If it cannot, use the RMC status command.
See Chapter 6.)
Compaq Confidential – Need to Know Required
Writer: Robert Young Project: AlphaServer DS20E System Comments:
Part Number: ER-K8F6W-UA .A01 File Name: l-ch11 Using the SRM Console.doc Last Saved On: 10/4/99 2:05 PM
Status
good
good
good
good
good
0:00
Temperature, Fans, Power Supplies Normal
0:00
Temperature, Fans, Power Supplies Normal
Using the SRM Console 11-15