1. Type the RMC escape sequence (not echoed).
^]^]RMC
RMC>
NOTE: From RMC command mode, you can change the escape sequence for invoking
RMC, if desired. Use the setesc command to change the sequence. Be sure to record
the new escape sequence.
2. To terminate the modem connection, enter the RMC hangup command.
RMC> hangup
If the modem connection is terminated without using the hangup command or
if the line is dropped due to phone-line problems, the RMC will detect carrier
loss and initiate an internal hangup command. If the modem link is idle for
more than 20 minutes, the RMC initiates an auto hangup.
NOTE: Auto hangup can take a minute or more, and the local terminal is locked out until
the auto hangup is completed.
Compaq Confidential – Need to Know Required
Writer: Robert Young Project: AlphaServer DS20E System Comments:
Part Number: ER-K8F6W-UA .A01 File Name: k-ch10 Managing the System Remotely.doc Last Saved On: 10/4/99 1:33 PM