server configured by this command. If it fails to send mail, the switch selects the next server in the list and tries to send
mail again. If it still fails, the system will repeat the process at a periodic interval. (A trap will be triggered if the switch
cannot successfully open a connection.)
Example
Console(config)# logging sendmail host 192.168.1.200
Console(config)#

logging sendmail level

This command sets the severity threshold used to trigger alert messages.
Syntax
logging sendmail level level
level -One of the system message levels (page 4-50). Messages sent include the selected level down to level 0. (Range:
0-7; Default: 7)
Default Setting
Level 7
Command Mode
Global Configuration
Command Usage
The specified level indicates an event threshold. All events at this level or higher will be sent to the configured email
recipients. (For example, using Level 7 will report all events from level 7 to level 0.)
Example
This example will send email alerts for system errors from level 4 through 0.
Console(config)#logging sendmail level 4
Console(config)#
logging sendmail source-email
This command sets the email address used for the "From" field in alert messages. Use the no form to delete the source email
address.
Syntax
[no] logging sendmail source-email email-address
email-address -The source email address used in alert messages. (Range: 1-41 characters)
Default Setting
None