Network-Access Max-Mac-Count - Planet SGSD-1022 User Manual

Layer 2 managed switches
Hide thumbs Also See for SGSD-1022:
Table of Contents

Advertisement

assignments are not restored.
The RADIUS server may optionally return a VLAN identifier list. VLAN identifier list is carried in the
"Tunnel-Private-Group-ID" attribute. The VLAN list can contain multiple VLAN identifiers in the format "1u,2t," where "u"
indicates untagged VLAN and "t" tagged VLAN. The "Tunnel-Type" attribute should be set to "VLAN," and the
"Tunnel-Medium-Type" attribute set to "802."
Example
Console(config-if)#network-access mode mac-authentication
Console(config-if)#

network-access max-mac-count

Use this command to set the maximum number of MAC addresses that can be authenticated on a port via all forms of
authentication. Use the no form of this command to restore the default.
Syntax
network-access max-mac-count count
no network-access max-mac-count\
count - The maximum number of authenticated MAC addresses allowed. (Range: 1 to 2048; 0 for unlimited)
Default Setting
2048
Command Mode
Interface Configuration
Command Usage
The maximum number of MAC addresses per port is 2048, and the maximum number of secure MAC addresses
supported for the switch system is 1024. When the limit is reached, all new MAC addresses are treated as an
authentication failed.
Example
Console(config-if)#network-access max-mac-count 5
Console(config-if)#
mac-authentication intrusion-action
Use this command to configure the port response to a host MAC authentication failure. Use the no form of this command to
restore the default.
User's Manual of SGSD-1022 / SGSD-1022P
474
SGSW-2840 / SGSW-2840P