Install And Wire Telephones And Trunks; Dcp, Analog, And Isdn-Bri - Avaya CMC1 Installation Manual

Installation, upgrades and additions for media gateways
Table of Contents

Advertisement

Add Translations
1
Refer to Administrator's Guide for Avaya Communication Manager to add new terminals.

Install and Wire Telephones and Trunks

NOTE:
Only 1 pair of wires is available for emergency transfer, and 1 pair of wires is available for
attendant console power.
This section provides wiring examples of installation procedures. These are examples only and actual
wiring procedures may vary at each site.
The system can connect to all DTE terminals. The system can have RS-232 (or EIA-232) or DCP
interfaces.
All wiring pinouts for port circuit packs are in the tables at the end of this chapter.
Refer to
Figure 21, Example MDF Connections,
circuit packs. The figure shows the colors of the punch-downs and is best viewed from CD-ROM or on-
line.
After installing the hardware, the data for the system and telephone features is administered. These
procedures are provided in Administrator's Guide for Avaya Communication Manager.

DCP, analog, and ISDN-BRI

The 302D Attendant Console describes a typical telephone connection. This information is typical of the
603E, 84xx (4-wire), and 94xx telephones. The attendant console always requires auxiliary (adjunct)
power (-48 VDC). See
can be powered by the system through the AUX connector. The primary console should be powered from
the system so it has the same power failure backup as the system.
The maximum cabling distance for the console powered from the cabinet is 350 feet (100 m) using 24
AWG (#5) (0.26 mm
The general steps to connect a telephone are:
1
Choose a device to connect such as a 302D Attendant Console.
2
Choose the port circuit pack and its carrier and slot number, such as TN754C, Cabinet 1, Carrier
A, Slot 06.
3
Choose a port circuit on the port circuit pack, such as Port 05.
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004
Figure 32, 302D to Digital Line Circuit Pack Wiring,
2
) wire.
Installing and Cabling the Cabinets
Install and Wire Telephones and Trunks
on page 55 for punch-down information for common
on page 76. Only 1 console
75

Advertisement

Table of Contents
loading