Table 25: Trunk/Test Switches
Switch
Number
1
2
3
4
5
6
7
8
9
10
11
12
4
Connect a 25-pair cable between the male RJ21 25-pair connector on the 808A and the yellow
field on the MDF.
the pinouts.
5
Make cross-connections for each emergency trunk/emergency station pair. See
Connections for Telephone Used for Emergency Transfer,
Connections for Telephone Used for Emergency Transfer and as Normal Extension,
6
On the trunk identification label at the bottom of the panel, record the trunk line, extension, and
location for each circuit.
7
To each voice terminal designated as an emergency terminal, attach a label identifying it as such.
The labels are provided with the unit.
8
Check the system for normal operation as follows:
a
Place the test switch (switch 12) in NORMAL OPERATION.
b
Ensure the power supply is providing -48 VDC at 80 mA maximum. The power LED
should be ON.
c
Check wiring connections.
d
Verify there is dial tone on all emergency transfer sets.
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004
Install Emergency Transfer Unit and Associated Telephones
Circuit
Number
1
1
2
2
3
3
4
4
5
5
Not Used
Test Switch
Table 26, Pin Assignments for 25-Pair Connector on 808A,
Installing and Cabling the Cabinets
on page 124 shows
Figure 65,
on page 126 and
Figure 66,
on page 127.