DEFINITY AUDIX Power Procedures

DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system's power unit notifies technicians to shut down the DEFINITY
AUDIX System prior to powering down the system.
1
Log into the AUDIX System as craft.
2
Type reset system shutdown and press Enter.
3
Press Enter again to start the shutdown process.
4
The
SHUTDOWN Completed
takes about 2 minutes.
5
You can now shut down the carrier or remove the AUDIX System for service.
CAUTION:
If leaving AUDIX System in the carrier, back it out about 2 in. (5 cm) to eliminate the
possibility of damage due to power surges.
Power Up the AUDIX System
If the AUDIX was removed from the cabinet:
1
Re-install the AUDIX and allow it to power up automatically.
2
Check for AUDIX System errors.
If the AUDIX remained in the cabinet but the cabinet was powered down:
1
Reseat the AUDIX
2
Power up the cabinet. The AUDIX reboots automatically.
3
Check for AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet was not powered down:
1
At the AUDIX console, hold the crtl key and enter cc.
2
Enter 5 at the prompt. In about 2 minutes, the AUDIX boots up.
3
When the system initialization is complete, log in as craft.
4
Check for AUDIX System errors.
176
message appears when the AUDIX is successfully shut down. This
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004