Adding or Removing Hardware
Add DCS Interface
For further information about DCS, refer to the following documents:
•
AT&T System 75/85 Network and Data Services Reference Manual
•
System 75 Application Notes Network Services
•
Administration for Network Connectivity for Avaya Communication Manager
Add Circuit Packs
A TN464GP, TN767C, or TN760 DS1 circuit pack is required for PPP connections. A TN799C or higher
C-LAN circuit pack is also required.
1
Determine the port assignments of the circuit packs to be added.
If a C-LAN circuit pack is already in the system, you do not need a second C-LAN circuit pack
for DCS. If your system already has a C-LAN, skip the following
section. You do not need to power down the cabinet to install any of these circuit packs.
Administer the Bus Bridge
1
Type change system-parameters maintenance and press Enter.
2
On Page 2, Type y in the
3
Choose the port bandwidths or use the default and submit the form.
4
Verify the bus bridge LED is lit on the C-LAN circuit pack. This indicates that the packet bus is
enabled.
Test the Packet Bus and Control-LAN Circuit
Pack
1
Type test packet port-network 1 long and press Enter. For more detail about these tests, refer to
the "test pkt command" section in Maintenance for Avaya DEFINITY Server CSI.
232
field.
PKTINT 2
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Administer the Bus Bridge