Upgrading R9csi/R10csi to Avaya Communication Manager on an Avaya DEFINITY Server CSI
Task table
Disable scheduled maintenance
and alarm origination
To prevent scheduled daily maintenance from interfering with the upgrade:
1
Type change system-parameters maintenance and press RETURN.
2
If scheduled maintenance is in progress, set the
time.
or
If scheduled maintenance is not in progress, set the
will be completed.
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes 90 minutes, set the
Start Time
CAUTION:
If you do not disable Alarm Origination, the system can generate alarms, resulting in
unnecessary trouble tickets.
3
Type neither in the
NOTE:
Disabling alarm origination prevents the system from generating alarms, thus preventing
unnecessary trouble tickets.

Check link status

1
Enter display communication-interface links and press RETURN.
2
Note all administered links.
3
Type status link number and press RETURN for each administered link.
Check the following fields for the values listed:
Link Status
Service State
NOTE:
For Release 7 and later, the only way to determine if an ISDN-PRI D-Channel is up is to
type status signaling group and press RETURN.
4
If any of the links are not up, take the necessary corrective action to restore the link before
continuing with the upgrade.
188
field to 21:30.
Alarm Origination to OSS Numbers
= connected
= in service
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
field to 1 minute after the current
Stop Time
field to a time after the upgrade
Start Time
field and press ENTER
June 2004