Avaya CMC1 Installation Manual page 118

Installation, upgrades and additions for media gateways
Table of Contents

Advertisement

Installing and Cabling the Cabinets
Install Off-Premises Station Wiring
Figure 63: Connections to 24 Out-of-Building Telephones
3
Figure notes
1
Locally engineered cables
2
Multi-pair protector units (primary
protectors with heat coils or
equivalent with sneak current
protection)
3
B25A cable
4
Concentrator cable (WP90929 List 1)
5
356A adapter
6
Out-of-building wiring
Circuit Protectors
Carbon block, or equivalent protection is required at both building entrances. Also sneak current
protection is required. Protection can be provided by a 4-type protector or a 3-type protector plus a
separate sneak current protector. The 4-type protector is equipped with a heat coil.
The 4-type protector is the preferred device. For installations not using primary protection, 4-type
protectors should always be used. When the 3-type protector is already installed, a separate sneak current
protector is required. The multi-pair protector units and the off-premises cabling must be locally
engineered. Connectorized multi-pair protector units (female 25-pair connector) are recommended.
23
shows the recommended protectors.
118
1
6
2
2
8
10
9
12
11
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
5
5
4
5
crdf24o RPY 012398
7
Out-of-building analog telephones
8
Part of MDF
9
Station side (white field)
10
System side (purple field)
11
Cross-connect jumpers
12
To TN2183, TN769, or TN746B analog
line circuit pack
7
7
7
7
7
7
Table
June 2004