Avaya CMC1 Installation Manual page 117

Installation, upgrades and additions for media gateways
Table of Contents

Advertisement

Figure 62: Connections for 1 to 8 Out-of-Building Analog Telephones
5
Figure notes
1
Locally engineered cables
2
Out-of-building wiring
3
Multi-pair protector units (primary
protectors with heat coils or
equivalent with sneak current
protection)
4
356A adapter
5
B25A cable
Figure 63
shows the connections for up to 24 off-premises analog telephones. Concentrations of analog
line pairs are used at both buildings to minimize the off-premises wiring required. At the MDF, jumpers
must be connected between 1 row/connecting block in the white field and up to 3 rows/connecting blocks
in the purple field. At the station location, a WP-90929, List 1 Concentrator Cable is used. There are 8
station appearances on each of the 3 fingers of the concentrator cable.
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
June 2004
1
2
3
3
7
8
9
10
5
6
7
8
9
10
11
Installing and Cabling the Cabinets
Install Off-Premises Station Wiring
4
5
11
crdfobt RPY 012398
Out-of-building analog telephones
Part of MDF
Station side (white field)
System side (purple field)
Cross-connect jumpers
To analog line circuit pack (TN2183,
TN769, or TN746B)
6
6
117