Screen Reference
RECALL TIMING
Disconnect Timing (msec)
Appears when the Flashhook Interval field is n.
Valid entries
80 to 1250 (in
increments of 10).
Flashhook Interval
Valid entries
y
n
Forward Disconnect Timer (msec)
Valid entries
25 to 1500 (in
increments of 25).
Lower Bound (msec)
The lower bound of the station-to-switch recall signal timing interval in milliseconds. Specifies
the lower bound of the flashhook interval. Appears when the Flashhook Interval field is y.
Valid entries
80 to 1250 (in increments of 10).
1276 Administrator Guide for Avaya Communication Manager
Usage
An on-hook that lasts for a period of time less than this value will be
ignored; greater than or equal to this value will be regarded as a
disconnect.
Usage
Enter y to indicate that a flashhook interval (recall window) is required. If a
y is entered, Upper Bound and Lower Bound appear.
If n is entered, Disconnect Timing appears.
Usage
Specify the duration of a momentary disconnect sent by the server/switch
to an analog station user when that user is the last party still off-hook on a
call.
Usage
Specify the lower bound of the flashhook interval.