1516 Administrator Guide for Avaya Communication Manager
Ringing Signal Voltage, Frequency, and Cadence
25 Hz, 35 to 90 Volts rms superimposed on 66 V dc, 1 sec
on, 4 sec off. Note that 50 Hz is recommended, and
another cadence may be 0.4 sec on, 0.2 sec off, 0.4 sec
on, 4 sec off
ETSI countries: 30 Volts rms, superimposed on a DC
voltage of 50 Volts, 25 or 50 hz, cadence of 1 sec on, 5 sec
off
75V at 24Hz with a cadence of 0.4 seconds on, 0.2
seconds off, 0.4 seconds on and 2.0 seconds off.
25 Hz, 70 +/- 20 Vrms superimposed on 48Vdc Cadence 1
sec on, 4 sec off, flash hook is 100 ms
25 Hz, 25 to 75 Volts rms superimposed on 48 V dc, 1 sec
on , 3 sec off
Korea : 20 Hz , 75 to 85 Volts (AC) , Cadence : 1 sec on, 2
sec off
ETSI countries: 30 Volts rms, superimposed on a DC
voltage of 50 Volts, 25 or 50 hz, cadence of 1 sec on, 5 sec
off
U.K. : 15 to 26.25 Hz, 25 to 100 Volts rms superimposed
on 48 V dc, 0.35 on, 0.22 off then start in at any point in:
0.4 sec on, 0.2 sec off, 0.4 sec on, 2 sec off. Note 1: 48v
DC may be present during the whole cadence or may be
confined to silent periods. Note 2: Some exchanges
provide a facility known as immediate ring; in this case an
initial burst of ringing 20 msec to 1 sec in length
immediately precedes switching to any point in the normal
ringing cycle.
Ireland: 25 Hz, 30 to 90 Volts rms superimposed on 50 V
dc, 0.4 sec on, 0.2 sec off, 0.4 sec on, 2 sec off another
possible cadence is 0.375 sec on, 0.250 sec off, 0.375 sec
on, 2 sec off.
ETSI countries: 30 Volts rms, superimposed on a DC
voltage of 50 Volts, 25 or 50 hz, cadence of 1 sec on, 5 sec
off