Avaya Communication Manager Administrator's Manual page 1626

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Screen Reference
End-to-End Signaling
This field appears when the Group Type field is cpe (customer-provided equipment trunk
groups). Auxiliary equipment such as paging equipment and music sources might be connected
to Avaya Communication Manager by auxiliary trunks. Communication Manager might send
DTMF signals (touch tones) to these devices. This field sets the duration of these tones.
Valid entries
60 to 360 ms in
increments of 10
Note:
For trunks that do not receive real answer supervision, a "connect" Event report
Note:
is sent when the Answer Supervision Timeout occurs.
Expected Digits
Note:
Set this field to blank if the Digit Treatment field is set to insert and the Digits
Note:
field contains a feature access code (for example, AAR or ARS) followed by
digits. In this case, the number of digits expected are set on the AAR and ARS
Digit Analysis Table and AAR and ARS Digit Conversion Table.
Valid entries
1 to 18
Extended Loop Range
This field appears only for a DID trunk group and is used only with the TN459A circuit pack.
Valid entries
y/n
1626 Administrator Guide for Avaya Communication Manager
Usage
Use this field to set the duration in milliseconds of the touch-tone signal
that is sent to the connected equipment.
Usage
Enter the number of digits that the far-end media server or switch sends
for an incoming connection. If your end is absorbing digits on this trunk
group, the entry in this field must be larger than the entry in the Digits
field.
If you leave this field blank, you cannot administer digit absorption.
Usage
Enter y or n depending on the distance between the central office and
your server. If greater than the required distance, then the field should be
y.