Incoming Partial Dial (sec)
This timer appears only if the Incoming Dial Type field is rotary.
Valid entries
5 to 255 in increments of 1
Note:
This timer is never sent to TN429 ports.
Note:
Incoming Seizure (msec)
This field appears when the Direction field is incoming or two-way, and, when applicable, the
Trunk Type field is cont. Only TN429, TN438 (any release), TN 447, TN464C (or later), TN465
(any release), TN767, TN2138, TN2140, TN2147, TN2184, and TN2199 ports receive this
timer. For DID trunks, only TN2199 and TN429D (or later) receive this timer.
Valid entries
20 to 2550 in
increments of 10
Normal Outgoing Seize Send (msec)
This field appears only if the Trunk Type field is dis and the trunk group Direction field is
two-way or outgoing. Only TN2140 ports receive this timer.
Valid entries
10 to 990 in
increments of 10
Usage
Enter the maximum time allowed between incoming rotary digits.
Usage
Enter the duration of the shortest incoming seizure signal your server
running Communication Manager can recognize. For ICLID, set this field
to 120. The field cannot be blank.
Usage
Enter the duration of the signal your server running Communication
Manager sends for an outgoing seizure.
Trunk Group
Issue 2.1 May 2006