SmartWare Software Configuration Guide
Example: Display PPP link information
node(cfg)#show ppp links 4
PPP Link Information:
=====================
Link:
ID:
Name:
Protocols:
LCP:
ID:
Name:
State:
Conf-Req send rate:
Max. Conf-Req:
Term-Req send rate:
Max. Term-Req:
Echo-Req send rate:
Max. Echo-Req:
Local ID:
Remote ID:
Local configured options:
Magic Number = 0x00000000
MRU = 1492 [68,1492]
ACCM = 0xffffffff
Local acknowledged options:
Remote configured options:
Magic Number = 0xb89d9e6b
MRU = 1492 [68,1492]
ACCM = 0xffffffff
Authentication Protocol = { PAP }
Remote acknowledged options:
MRU = 1492 [68,1492]
Magic Number = 0xb89d9e6b
Authentication Protocol = { PAP }
Remote denied options:
Remote rejected options:
PAP:
ID:
Name:
State:
Direction:
Local authentication:
ID:
Password:
Success:
Remote authentication:
ID:
Password:
Success:
Auth-Req send rate:
Max. Auth-Req:
PPP configuration task list
0
ethernet 0 0 0/pppoe/ppp_green
LCP, PAP
0
ethernet 0 0 0/pppoe/ppp_green
Opened
3000ms
10
3000ms
2
10000ms
3
100000020390
0
ethernet 0 0 0/pppoe/ppp_green
Opened
supplying
patton
patton
Greetings!!
3000ms
3
30 • PPP configuration