Wiring Diagram - §3 - Epson ColorPage EPL-C8200 Service Manual

Color laser printer
Hide thumbs Also See for ColorPage EPL-C8200:
Table of Contents

Advertisement

EPSON ColorPage EPL-C8200
A.3.3.3 Wiring Diagram - §3
Signal Name
DTS CONT
DTS ON (L) 24VDC
2BTR MONI
2BTR CONT
2BTR ON (L) 24VDC
1BTR MONI
1BTR CONT
1BTR ON (L) 24VDC
DB DC CONT
DB DC ON (L) 24VDC
DB AC ON (L) 24VDC
BCR DC CONT
BCR ON (L) 24VDC
BCR
DB
1st BTR
2nd BTR
DTS
Chapter A
Appendix
Table A-22. Wiring Diagram - §3
Output control signal for the DTS output. (Analog)
Control signal to turn the DTS output ON/OFF.
Current monitor signal for the 2nd BTR output. (Analog)
Output control signal for the 2nd BTR output. (Analog)
Control signal to turn the 2nd BTR output ON/OFF.
Voltage monitor signal for the 1st BTR output. (Analog)
Output control signal for the 1st BTR output. (Analog)
Control signal to turn the 1st BTR output ON/OFF.
Output control signal for the DB output (DC component). (Analog)
Control signal to turn the DB output (DC component) ON/OFF.
Control signal to turn the DB output (AC component) ON/OFF.
Output control signal for the BCR output (DC component). (Analog)
Control signal turn the BCR output ON/OFF.
Charging output to the BCR (Drum Cartridge) from HVPS.
• This is output in response to the BCR DC CONT signal when the BCR ON(L) 24VDC signal is
turned on.
Output from the HVPS to the Developer Contact Assembly (Magnet Roll in the Developer
Assembly).
• This signal is output after overlaying the AC component (DB AC) on the DC component.
• This is output in response to the DB DC CONT signal when the DB DC ON(L) 24VDC signal is
turned on.
Output for the 1st transfer from the HVPS to the 1st BTR (Transfer Assembly)
• This signal is output in response to the 1BTR CONT signal when the 1BTR ON(L) 24VDC signal
is turned on.
Output for the 2nd transfer from the HVPS to the Contact Roll (Back Up Roll) (Transfer Assembly).
• This signal is output in response to the 2BTR CONT signal when the 2BTR ON(L) 24VDC signal
is turned on.
Output from the HVPS to discharge the electricity on the Detack Saw (2nd BTR Assembly).
• This signal is output in response to the DTS CONT signal when the DTS ON(L) 24VDC signal is
turned on.
Description
Revision A
A-37

Advertisement

Table of Contents
loading