Fip-1.1 Y/M/C/K Toner Cartridge Toner Is Out - Epson ColorPage EPL-C8200 Service Manual

Color laser printer
Hide thumbs Also See for ColorPage EPL-C8200:
Table of Contents

Advertisement

EPSON ColorPage EPL-C8200

FIP-1.1 Y/M/C/K TONER CARTRIDGE TONER is Out

Step
Check point
Perform the preliminary inspection.
Parts to inspect:
1
Developer Assy, DISPENSE MOTOR ASSY,
DEVE.CONTACT ASSY, ADC SENSOR ASSY,
MCU PWB
Isolation: Engine or controller?
Run the Engine test print or diagnostic test print. (10
2
pages for each single and continuous print)

Is the result normal?
Check: Dispense Motor installation
3
Is the Dispense Motor installed properly?
Check: Dispense Motor

Is the Dispense motor working properly? (Check it by
4
using the diagnostic tool.)
Diag Tool: Digital Output Test, Device Code: 25
Check: DEVE. CONTACT ASSY

5
Is the contact area deformed or lodged with any
foreign matter?
Check: Photo sensor surface of the ADC SENSOR

6
Is the sensor surface smeared or lodged with any
foreign matter?
Check: ADC SENSOR

Is the ADC SENSOR functioning properly? (Check it
7
by using the diagnostic tool.)
Diag Tool: Digital Input Test, Device Code: 18, 33
Check: ADC SOLENOID

Is the ADC SOLENOID functioning properly?
8
Diag Tool: Digital Output test, Device code: 36
Check: Developer Assy
9
Replace the relevant Developer Assy.

Does the problem still occur?
Chapter 5
Troubleshooting
Finding & Remedy
Yes
Replace/reinstall the defective part(s).
Check the Controller PWB.
If the problem still occurs, go to step 3.
• With the diagnostic tool, go to step 4.
• Without the diagnostic tool, go to FIP-
2.36 "DISPENSE MOTOR ASSY is
Defective".
If the problem still occurs, go to step 5.
Go to Step 5.
Replace the DEVE. CONTACT ASSY.
• With the diagnostic tool, go to step 8.
• Without the diagnostic tool, go to FIP-
2.21 "ADC SOLENOID is Defective".
If the problem still occurs, go to step 5.
Replace the PCU PWB.
Replace the PCU PWB.
Replace the MCU PWB.
No
Go to Step 2.
Go to Step 3.
Reinstall the DISPENSE MOTOR ASSY.
Go to FIP-2.36 "DISPENSE MOTOR
ASSY is Defective".
Go to FIP-2.38 "HVPS is Defective"
If the problem still occurs, go to FIP-2.19
"ROS ASSY is Defective".
• With the diagnostic tool, go to step 7.
• Without the diagnostic tool, go to FIP-
2.20 "ADC SENSOR is Defective".
Go to FIP-2.20 "ADC SENSOR is
Defective".
Go to FIP-2.21 "ADC SOLENOID is
Defective".
Problem solved.